WinBuilder [067]


       Scripts

 0 - General
 1 - Main Process

 2 scripts processed.



      Warnings

  Exiting..


       %BaseDir% = D:\Documents and Settings\ah\Desktop\vistape006rc5-base
(winbuilder's path is replaced by the variable %basedir% to make the log easier to read)


       [Script]  0 - General

 [Info]  File [%BaseDir%\Projects\VistaPE\Build\Standard-0-general.script] Version [6]
 [Info]  Preparing...
 [Ignore]  IF - File already exists: [D:\WINDOWS\system32\drivers\fltmgr.sys] evaluated string: [If,notExistFile,"%WindowsDir%\system32\drivers\fltmgr.sys",run,%ScriptFile%,FltMgr]
 [Ignore]  IF - File already exists: [D:\WINDOWS\system32\drivers\wimfltr.sys] evaluated string: [If,notExistFile,"%WindowsDir%\system32\drivers\wimfltr.sys",run,%ScriptFile%,WinUtil]
 [Ignore]  IF - File already exists: [%BaseDir%\Projects\Tools\wimutil.exe] evaluated string: [If,notExistFile,"%Tools%\wimutil.exe",run,%ScriptFile%,WinUtil]
  Script time: 250 miliseconds



       [Script]  1 - Main Process

 [Info]  File [%BaseDir%\Projects\VistaPE\Build\Standard-1-Main.Script] Version [6]
 [Success]  IF - [true] is equal to: [true]


 Processing section: [ClearTarget] from file: [%BaseDir%\Projects\VistaPE\Build\Standard-1-Main.Script]

 [Ignore]  IF - Directory does not exist: [%BaseDir%\Target] evaluated string: [If,ExistDir,"%TargetDir%",Echo,"Deleting [%targetdir%]"]
 [Ignore]  IF - Directory does not exist: [%BaseDir%\Target] evaluated string: [If,ExistDir,"%TargetDir%",DirDelete,"%TargetDir%"]
 [Ignore]  IF - Directory does not exist: [%BaseDir%\Target] evaluated string: [If,ExistDir,"%TargetDir%",Exit,"%TargetDir% could not be deleted!"]


 [Ignore]  IF - Directory already exists: [%BaseDir%\ISO] evaluated string: [If,notExistDir,%ISODir%,DirMake,"%ISODir%"]
 [Ignore]  IF - Directory already exists: [%BaseDir%\Temp] evaluated string: [If,NotExistDir,"%BaseDir%\Temp",DirMake,"%BaseDir%\Temp"]
 [Ignore]  IF - Directory already exists: [%BaseDir%\src] evaluated string: [If,NotExistDir,"%BaseDir%\src",DirMake,"%BaseDir%\src"]


 Processing section: [Find-VistaCD] from file: [%BaseDir%\Projects\VistaPE\Build\Standard-1-Main.Script]

 [Info]  Detecting Microsoft Windows Vista DVD...
 [Success]  IF - File exists: [E:\vista\sources\boot.wim] executing command: [Set,%SDIR%,%SourceDir%]
 [Success]  SetVar - Sucessfully changed the value of [%SDIR%] to: [%SourceDir%]
 [Success]  IF - File exists: [E:\vista\sources\boot.wim] executing command: [Set,%VISTACD%,OK]
 [Success]  SetVar - Sucessfully changed the value of [%VISTACD%] to: [OK]
 [Success]  System - Refreshing all variables
 [Success]  IF - File exists: [E:\vista\sources\boot.wim] executing command: [Echo,Vista DVD found [%SDIR%]]
 [Info]  Vista DVD found [E:\vista]
 [Success]  IF - File exists: [E:\vista\sources\boot.wim] executing command: [Set,%FRESULT%,yes]
 [Success]  SetVar - Sucessfully changed the value of [%FRESULT%] to: [yes]


 [Ignore]  IF - [ok] is equal to [ok] evaluated string: [If,"%VISTACD%",NotEqual,"OK",run,%ScriptFile%,Find-WAIK]
 [Ignore]  IF - [yes] is equal to [yes] evaluated string: [If,"%FRESULT%",NotEqual,"yes",run,%ScriptFile%,process-NoSource]


 Processing section: [MountWIM] from file: [%BaseDir%\Projects\VistaPE\Build\Standard-1-Main.Script]

 [Info]  Mounting WIM file...
 [Ignore]  IF - [%waik%] is not equal to [ok] evaluated string: [If,"%WAIK%",Equal,"OK",ShellExecute,Hide,"#$q%tools%\wimutil.exe#$q","mount #$q%SDIR%\winpe.wim#$q #$q%IWTemp%#$q"]
 [Success]  IF - [ok] is equal to: [ok]
 [Success]  Shellexecute: [Hide] using: ["%BaseDir%\Projects\Tools\wimutil.exe"] with parameters: [mount "E:\vista\sources\boot.wim" "%BaseDir%\src" /2]
 [Success]  IF - File doesn't exist: [%BaseDir%\src\windows\regedit.exe] executing command: [run,%ScriptFile%,process-NoMountWIM]


 Processing section: [process-NoMountWIM] from file: [%BaseDir%\Projects\VistaPE\Build\Standard-1-Main.Script]

 [Success]  Message: Can not mount WIM file. You must install "Windows Image Mini-Filter Driver" by Microsoft to you system. Exiting...

  Exiting..


  Script time: 32 seconds and 860 miliseconds
  Project time: 33 seconds and 141 miliseconds





You can post this log on the Boot Land forums whenever you need help to properly debug the errors on this project
More detailed documentation can be found on our wiki

WinBuilder 2006-2007
Nuno Brito